| SPECIFICATIONS |
| Specifications
apply after 30 minute warm-up, ambient 5?C to 40?C |
| FREQUENCY |
| Frequency Range: |
150kHz to 2000MHz |
| Setting
Resolution: |
10Hz by direct keyboard entry,
or in user-set increments of 10Hz to 999?999MHz by rotary control or
increment?decrement keys. |
| Display
Resolution: |
10Hz |
| Phase Noise: |
-116dBc/Hz at 25kHz offset,
500MHz carrier. |
| Residual FM (FM
Off): |
Equivalent peak
deviation for 300Hz to 3?4kHz B/W: 10Hz
at 500MHz carrier |
| REFERENCE
FREQUENCY |
| Options: |
Internal or External (via rear panel BNC) |
| Internal Accuracy: |
+/- 1 ppm over temperature
range 1 5?C to 30?C; +/- 2 ppm over 5?C to 40?C. |
| Internal Stability: |
< +/-1ppm/year ageing. |
| Internal Ref. Out: |
10MHz from 50 Ohms, amplitude 2V pk-pk into
50 Ohms. |
| External Ref In: |
10MHz into 50 Ohms, amplitude 2V pk-pk to 5V pk-pk. |
| OUTPUT
LEVEL |
| Output Level
Range: |
?127dBm to +7dBm (0?1?V to
500mV into 50W).
?127dBm to +1dBm in AM mode. |
| Setting
Resolution: |
0?1dB (or 0?01?V to 1mV) by
direct keyboard entry, or in user-set increments of 0?1dB to 100dB (or
0?01?V to 100mV) by rotary control or increment?decrement keys. |
| Accuracy: |
Better than ? 2dBm. |
| Harmonics: |
<-25dBc at +7dBm. |
| Sub-Harmonics: |
<-25dBc at +7dBm. |
| Non-Harmonic
Spurii: |
<?60dBc at >62.5MHz, <?50dBc at <62.5MHz. |
| Carrier Leakage: |
<0.5uV generated into a 50W
load by a 2 turn 25mm loop, at 25mm from the generator with output set
to <-10dBm into a 50W
sealed load. |
| Output Impedance: |
50W |
| Output Connector: |
TYPE N |
| Reverse
Protection: |
50V DC, up to 25W from 50 Ohm source, LED indication |
| Output Switch: |
RF OUT on-off switch with LED
for ON status. |
|
MODULATION SOURCE |
| Type: |
Internal from built-in sine wave generator, or external from front panel BNC. |
| Internal: |
400Hz or 1kHz sine, signal also available as an output. |
| External: |
Calibrated for 1V rms sine, input impedance
600 Ohms. |
| FREQUENCY
MODULATION |
| Max. Peak Deviation: |
See Table below. |
| Setting
Resolution: |
0?5kHz by direct keyboard
entry, rotary control or increment?decrement keys. |
| Deviation
Accuracy: |
<?10% ?0.5kHz for 1kHz Internal or 1kHz / 1Vrms External Modulation. |
| External
Modulation |
100Hz - 300kHz (? 2dB relative to 1kHz). |
| Distortion: |
< 2% at 1kHz modulation, max. deviation (300-3.4kHz bandwidth). |
| PHASE
MODULATION |
| Max. Peak Deviation: |
See Table below. |
| Setting
Resolution: |
0.05 rads for <10.0rads deviation, 0.1 rads for >10.0rads deviation. |
| Deviation
Accuracy: |
<?10% ?0.05rads for 1kHz Internal or 1kHz / 1Vrms External Modulation. |
| External
Modulation |
100Hz - 10kHz (?2dB relative to 1kHz). |
| Distortion: |
< 2% at 1kHz modulation, max. deviation (300-3.4kHz bandwidth). |
| AMPLITUDE
MODULATION |
| Max Mod. Depth: |
100%. |
| Setting
Resolution: |
0.5%. |
| Deviation
Accuracy: |
<? (5% setting +1%) for 1kHz Internal or 1kHz / 1Vrms External Modulation. |
| External
Modulation |
50Hz - 200kHz (?1dB relative to 1kHz). |
| Distortion: |
150kHz to 1GHz - <3% at 30%, <5%
at 70%1GHz to 2GHz - <5% at 30%,
<10% at 70% at 1kHz modulation, max. deviation (300-3.4kHz bandwidth). |
| INTERFACES |
| Full remote control facilities are available through both RS232 and GPIB interfaces |
| RS232: |
Variable Baud rate, 19200 Baud
maximum, 9-pin D-connector. Compatible with Thurlby Thandar ARC
(Addressable RS232 Chain). |
| GPIB (IEEE-488): |
Conforming with IEEE488?1 and
IEEE488?2. |
| GENERAL |
| Display: |
20 character x 4 row backlit
alphanumeric LCD |
| Data Entry: |
Keyboard selection of
frequency, amplitude, etc.; value entry by numeric keys or by rotary
control. |
| Stored Settings: |
Up to 9 complete instrument
set-ups may be stored in battery-backed memory. |
| Size: |
3U (130mm) height; half-rack
(212mm) width; 330mm long. |
| Weight: |
4?6 kg. (10 lb) |
| Power: |
230V, 115V or 100V nominal
50/60Hz, adjustable internally; operating range ?14% of nominal; 30VA
max. Installation Category II. |
| Options: |
19 inch
rack mounting kit. |
| ENVIRONMENTAL
& SAFETY |
| Operating Range: |
+5?C to 40?C, 20-80% RH. |
| Storage Range: |
?20?C to + 60?C. |
| Environmental: |
Indoor use < 2000m,
Pollution Degree 1. |
| Safety: |
Complies with EN61010-1. |
| EMC: |
Complies with EN61326 |