HA1600  - Description and Specifications

HA1600 - Mains & Harmonics Analyser

  Compliance quality measurements to EN61000-3-2
    and EN61000-3-3
  Measures peak or rms voltage or current, real
    or apparent power, power factor, phase etc.
  Tabular/histogram of 40 harmonics
  Voltage/current waveforms with masks
  Incorporates a full flicker meter
  Wide range of power connectors available
  320 x 240 pixel high-contrast display
  GPIB, RS232 and printer interfaces

  Larger Image

Overview

The HA1600 is a fast, easy to use mains and harmonics analyser with full graphical display. It is capable of continuous real-time analysis of both voltage and current. As a general purpose mains analyser it can measure Watts, VA Vrms, Vpk, Arms, Apk, Crest factors, THD, Power factor, Frequency and Inrush current.
As a harmonics analyser it is a quick and convenient instrument for pre-compliance measurements using normal mains supply and is capable of full compliance measurements to EN61000-3-2 in conjunction with a suitable power source. Capabilities include real-time Class D evaluation and visual display, continuous automatic calculation of harmonic limits to EN61000-3-2, inrush current analysis, and timed test sequences with analysis of fluctuating harmonics. As an option, the HA1600 can be operated as a conformance quality flicker meter in conformance with EN60868 and EN61000-3-3.
A printer interface is included for record keeping and archiving, along with an RS-232 interface  for use with PC based software or as part of a GPIB system.

High performance power analyser

The HA1600 is a high speed, high accuracy ac power analyser for single phase supplies of up to 16 amps RMS.
The supply to be measured is connected via a dedicated input cable independently of the supply to the instrument. The output to the load is via a front panel mounted ‘standard’ mains connector. A wide range of power connectors is available including most european national types.

Compliance-quality harmonics analyser

The HA1600 is suitable for pre-compliance measurements using a normal mains supply and is capable of full compliance measurements to EN61000-3-2 in conjunction with a suitable power source (such as the AC1000 from TTi).
Capabilities include real-time Class D evaluation and visual display, continuous calculation of harmonic limits to EN61000-3-2, inrush current analysis, and timed test sequences with analysis of fluctuating harmonics.

Compliance-quality flicker meter

The HA1600 includes the capability to operate as a compliance quality flicker meter in conformance with EN60868 and EN61000-3-3. Flicker severity can be measured in terms of Pst and Plt with analysis periods variable between 5 minutes and 2 hours.
Flicker severity can be measured in terms of Pst and Plt with analysis periods between 5 minutes and 2 hours. The graphical display can show Cumulative Probability, Voltage Deviation Failure as well as Pst values.

SPECIFICATIONS
MAINS ANALYSER
Measurement Circuit: Single Phase with standard mains connector.
Current Rating: 16A rms continuous, or national connector rating if lower.
Voltage Ranges: 115V (±200V pk) 230V (±400V pk).
Current Ranges: ±24mA pk to ±400A pk in fifteen 2:1 ranges.
Frequency Range: 45 - 66 Hz.
Shunt Resistance: 3mOhms.
Sampling Rate: 300 points per cycle.
Basic Accuracy: <0.2%.
Measured Parameters: Vrms, Vpk, Arms, Apk, Crest factors, THD, W, VA, Power factor, Frequency, Inrush current.
Monitor Outputs: Re-constructed Voltage and Current Signals.
HARMONICS ANALYSER
Measurements:1st harmonic to 40th harmonic.
Current Rating: 16A rms continuous, or national connector rating if lower.
Voltage Ranges: 115V (±200V pk) 230V (±400V pk).
Current Ranges: ±24mA pk to ±400A pk in fifteen 2:1 ranges.
Frequency Range: 45 - 66 Hz.
Shunt Resistance: 3mOhms.
Sampling Rate: 300 points per cycle.
Basic Accuracy: Better than 5% of limit or 0.2% of selected range whichever is the greater.
Display Modes: Numeric readout of parameters. Graphical Waveform Display with accumulate and max. hold facilities and Class D mask. Tabular and Histogram harmonics analysis with comparison to limits in the standards.
FLICKER METER
Measurement: Pst and Plt to EN60686 and EN61000-3-3.
Current Rating: 16A rms continuous, or national connector rating if lower.
Voltage Ranges: 115V (±200V pk) 230V (±400V pk).
Current Ranges: ±24mA pk to ±400A pk in fifteen 2:1 ranges.
Frequency Range: 45 - 66 Hz.
Shunt Resistance: 3mOhm.
Sampling Rate: 300 points per cycle.
GENERAL
Display: 320 x 240 pixel backlit LCD.
Interfaces: Parallel Printer, RS-232, Optional IEEE-488 (GPIB).
Instrument Supply: 230V or 115V ±14%, 48 to 65Hz.
Operating Range: +5°C to 40°C, 20-80% RH.
Storage Range: –10°C to +60°C.
Dimensions: 305 x 148 x 220mm (WxHxD)
Weight: 4.2kg
Safety: Complies with EN61010-1
EMC Compliance: Complies with EN61326-1
 Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications 
 without prior notice.

Thurlby Thandar Instruments Ltd.

Glebe Road, Huntingdon. Cambs. PE29 7DR  United Kingdom.  Tel: +44 (0)1480 412451
Fax: +44 (0)1480 450409  Email: sales@tti-test.com  Web www.tti-test.com

  Navigation: Products UK only < HOME > TTi Products Worldwide > Precision > EMC Measurement >>